Terms and Definitions

I-SOI-10

SOIC Installation TJ-70 Hot Air

1. Start with a heater temperature of 482°C (900°F) and adjust as necessary.

2. Install tip into ThermoJet® Handpiece using Tip Tool.

3. Apply a small bead of solder paste along the land pattern using a dispenser. (A)

4. Position component onto lands using a HandiPik® or tweezers. (B)

5. Starting at MINIMUM,adjust pressure output (on power supply) so hot air scorches a tissue from approximately 0.5cm (0.2”) away. (C)

6. Direct hot air over component with tip at a distance of 2.5cm (1.0”) to predry solder paste. (D)

7. When pre-drying is observed (paste has dull, flat appearance), bring tip closer (0.5cm [0.2”]) and slowly move tip along each row of leads to form proper solder fillets. (E)

8. Return ThermoJet® to its Tip & Tool Stand.

9. Clean, if required, and inspect.

PACE SensaTemp® or Intelliheat® Power Supply

TJ-70 ThermoJet®

Flat End Tip (See Chart on Back)

Pik & Paste Liquid Dispensing System

Tip Tool

HP-65 HandiPik®

Tweezer

Manual Solder Paste Dispenser

Solder Paste

Paste Dispense Needles

Cleaner

Product Image Dimensions Part Number
1121-0371-P1
0.060" I.D. 1121-0366-P1
Diameter: 0.060" I.D. 1121-0338-P1
Dimension A: A = 4.32mm (0.17") 1121-0330-P1